About Ekki Kurniawan (33212019)

  • Email: email
  • Biography: phD student

Posts by Ekki Kurniawan (33212019):

0

ANALISIS INSERTION LOSS PADA FILTER DAYA BERBASIS ELECTROMAGNETIC COMPATIBILITY (EMC)

Posted by Ekki Kurniawan (33212019) on December 16, 2014 in Uncategorized |

ABSTRAK

The growth of electronics technology is followed by increasing some kinds of frequency that circulating on the environment. The presence of those frequencies will decrease immunity and reliability of electronic equipments that should be improved by installation of filters. This paper is intended to look for a new filter topology, which is the most efficient from the various possible combinations. The filters installed before the equipments rectification system is called Electromagnetic Interference (EMI) filter. EMI filters are analyzed consists of harmonic filter and Low Pass Broadband Filter (LPBF). Single tone harmonic filter is used to dampen the additional grids frequency that appear ranging from 100 Hz to 2 kHz. LPBF will be combined to dampen the frequencies that higher than 2 kHz due to the effect of capacitance, induction or radiation of electromagnetic pulse from the events of Electrostatic Discharge (ESD), Electrical Fast Transient (EFT) and Surges. Some EMC  standards for transient immunity and harmonic current as set out in the standard IEC 61000-4-2, IEC61000-4-4, IEC 61000-4-5 and IEC 61000-3-2 were elaborated to determine the parameters of the filter. Analysis for the performance of the filter in the form of insertion loss (IL) uses the parameters of impedance,  admittance and transmission in in two port network. The results of calculations based on the standard values ofthe source and load impedance, with a cut-off frequency for harmonic filter is 150 Hz and 6.37 kHz for LPBF  shows that the parallel combination of the type a1 harmonic filter (series with the grid) with LPBF is the most  efficient.

Keywords: electronic equipment, EMC standards, EMI filter, harmonics, LPBF, IL

Silahkan Klik full-paper

0

Insertion Loss Analysis of Low Voltage Power Line Filter based on EMC Standards

Posted by Ekki Kurniawan (33212019) on December 16, 2014 in Prosiding/Konferensi |

Abstract This paper is intended to study Electromagnetic Compatibility (EMC) concept and filtering system as part of solution to handle Electromagnetic Interference (EMI) problems. Insertion Loss (IL) parameter from the various possible combinations were examined to choose the best performance of the new filter topology which is the most efficient. The filters installed before the […]

0

Perancangan Filter Pasif Untuk Mengatasi Harmonisa Pada Gardu Penyearahan Pusat Listrik Aliran Atas – PT KAI Commuter Jabodetabek Indonesia

Posted by Ekki Kurniawan (33212019) on May 6, 2013 in Prosiding/Konferensi |

Ppt Perancangan Filter Pasif Untuk Mengatasi Harmonisa Pada Gardu Perancangan Filter Pasif Untuk Mengatasi Harmonisa Pada Gardu Penyearahan Pusat Listrik Aliran Atas (Pdf file) Gardu Listrik KRL Stasiun UI Terbakar Sabtu, 24 Oktober 2009 16:08 WIB | 2.530 Views Pewarta: adit  Depok (ANTARA News) – Gardu listrik kereta rel listrik (KRL) di Stasiun Universitas Indonesia (UI), Depok, […]

0

Tugas Pertama Metoda Penelitian

Posted by Ekki Kurniawan (33212019) on May 4, 2013 in Uncategorized |

Welcome in “Good Morning” Spirit ! Assalamu’alaikum dan Salam Sejahtera kawan-kawan semua Berikut ini tugas pertama dari matakuliah Metoda Penelitian yang diampu oleh Doktor Dwi : Read paper: “How to Succeed in Graduate School: A Guide for Students and Advisors” Submit online your answer for the following questions (Deadline: Wednesday, 5 Sept at 23.55): What […]

0

Wawancara Dengan Profesor

Posted by Ekki Kurniawan (33212019) on October 25, 2012 in Motivasi, Uncategorized |

Wawancara pertama dengan profesor emeritus Sujana Safiie. Dilakukan hari senin tanggal 22 Oktober 2012.Mulai pukul 13.00 kami datang berdua bersama (Pa Alfi Satria) Ketika mau ditanya beliau  merendah,wah saya sudah tua, sudah pensiun kenapa harus diwawancara. 1.Apa perlunya Filsafat Ilmu matakuliah S3 ? Diawali dengan “Wow filsafat,pertanyaan yang tidak mudah untuk dijawab/berat ” Mhs S3 […]

0

Milestone S3

Posted by Ekki Kurniawan (33212019) on October 8, 2012 in Disertasi/Tesis, Motivasi, Prosiding/Konferensi |

Pengantar Saya  sangat berterimakasih kepada Bapak Prof Kuspriyanto, yang telah membuat milestone S3. Dengan Milestone ini insyaAllah akan membantu saya untuk mendapatkan ijazah Doktor dari ITB. Komentar saya adalah ” Ok”, dan akan mengusahakan agar milestone ini menjadi bagian rencana atau planning yang harus dikerjakan. Jumlah jam yang tertulis pada tabel tidaklah mutlak, bisa lebih […]

0

Sistem Chopper Untuk Penghemat Daya Pompa Air Rumah Tangga (Inovasi Kecil)

Posted by Ekki Kurniawan (33212019) on September 26, 2012 in Inovasi |

Pengantar Definisi-definisi: “Inovasi”(http://avin.filsafat.ugm.ac.id/downloads/hasildiskusi/kuliah%206.pdf).Inovasi adalah mengkreasikan dan mengimplementasikan sesuatu menjadi satu kombinasi baru (Schumpeter).Menurut Wess & Farr (dalam De Jong & Kemp 2003) adalah semua perilaku individu yang diarahkan untuk menghasilkan,memperkenalkan, dan mengaplikasikan hal-hal ‘baru’, yang bermanfaat bagi masyarakat ataupun berbagai level organisasi. Sistem Chopper Untuk Penghemat Daya Pompa Air  Rumah Tangga Dalam kehidupan rumah tangga […]

0

Teori Keberhasilan S3

Posted by Ekki Kurniawan (33212019) on September 18, 2012 in Uncategorized |

Teori keberhasilan S3 Motivasi kuat Beasiswa, dana untuk penelitian (bahan dan alat , transportasi dll) Mengikuti prosedur peraturan akademik (perwalian,perkuliahan dll) Membuat Jurnal  penelitian, Log book dll Buat Paper yang sesuai standar Submit untuk konferensi dan jurnal Sidang tertutup dan dan terbuka   Persamaan matematika (sementara) : Ax12  + By + Cz  =  Nilai Faktor […]

0

Prosiding 4th International Conference on Electrical Engineering and Informatics, ICEEI 2013

Posted by Ekki Kurniawan (33212019) on September 15, 2012 in Prosiding/Konferensi |

Full Paper –> Link to www.sciencedirect.com Abstract Indonesia islands are situated in equatorial region with relative high density of thunderbolt rate. As developing country Indonesia builds many generating plants. During lightning stroke, some spikes occurred in turbine-generator vibration monitoring systems. Electromagnetic compatibility (EMC) problem was happened in the systems. This paper proposes mitigation technique to […]

0

Contoh Jurnal Internasional

Posted by Ekki Kurniawan (33212019) on September 15, 2012 in Jurnal |

International Journal of Instrumentation Science 2012, 1(2): 21-24 DOI: 10.5923.j.instrument.20120102.03 Improvement by Voltage Profile by Static Var Compensators in Distribution Substation Guneet Kour1, G. S. Brar1, Jaswanti Dhiman2,* 1Department of Electrical Engineering, Baba Banda Singh Bhadur Engg College, Fatehgarh Sahib, Punjab  2Department of Electrical Engineering, Chandigarh College of Engineering & Technology (CCET), Chandigarh, India vernacular12@gmail.com, […]

Copyright © 2012-2021 Philosophy of Doctor Preparation All rights reserved.
This site is using the Desk Mess Mirrored theme, v2.2.4.1, from BuyNowShop.com.